Analysis of Vibrational Induced Structure Considering Rail and Seismic Load Using ETABS

Authors

  • Vaishali Barmate Department of Civil Engineering, UIT RGPV, Bhopal Madhya Pradesh, India Author
  • Amit Vishwakarma Department of Civil Engineering, UIT RGPV, Bhopal Madhya Pradesh, India Author

Keywords:

Tall Structure, Seismic Load, Force, Displacement, Damping, Vibration Level, Train- Induced Vibration

Abstract

In the past, buildings next to railroad tracks were not taken into account when designing them, which resulted in catastrophic damage to the buildings as well as fatalities. For these structures to be designed safely, the vibrational loading must diminish.
This study's case study is the Rani Kamlapati railway station in Bhopal, which was renovated by the Bansal Group and is the nation's first private railroad station. They suggested building a business complex and other structures close to the train station. Numerous practical and theoretical methods have been put forth for the prediction of vibrations caused by trains. A 3D finite element analysis was used to represent train movement and its impact on the nearby building in order to analyse the vibration near the railway in Bhopal. The operating measurements of the high-speed train served to validate the numerical model. In the experimental study, two examples are compared: one involves a structure next to a railway track that experiences vibration, and the other involves a typical construction.
Extended Three Dimensional Analysis of Building Systems is known as ETABS. Every step of the engineering design process is integrated by ETABS.
In the current state of the building business, the built structures are observed and generally demonstrate significance positivity. These structures are referred to as members such beams and columns in multi-story R.C. structures. High-rise buildings, steel structures, and concrete structures are the principal uses of this programme. The goal of the study is to analyse a high- rise structure with 19 floors (G+18) while taking seismic, dead, and live loads into account. Strength, serviceability, and stability are the design characteristics for high-rise structures. ETABS 2016 is the name of the software version utilized. In order to compare the results for the two scenarios, comparison parameters included determining the effects of lateral loads on moments, shear force, base shear and maximum displacement on structural systems.
              

Downloads

Download data is not yet available.

References

Regina Augusta Sampaio and Remo Magalhâes de Souza, [VIBRATION ANALYSIS OF A RESIDENTIAL BUILDING], MATEC Web of Conferences, (2015).

Chao Zou, Yimin Wang and Ziyu Tao, [Train-Induced Building Vibration and Radiated Noise by Considering Soil Properties], Sustainability 2020, 12, 937.

DR. K. CHANDRASEKHAR REDDY and G. LALITH KUMAR, [Seismic Analysis of High-Rise Buildings (G+30) by Using ETABS], International Journal of Technical Innovation in Modern Engineering & Science (IJTIMES), Volume 5, Issue 03, March- 2019.

Denise-Penelope N. Kontoni and Ahmed Abdelraheem Farghaly, [Mitigation of train- induced vibrations on nearby high-rise buildings by open or geofoam-filled trenches], JOURNAL OF VIBROENGINEERING. MARCH 2020, VOLUME 22, ISSUE 2.

Sayyed Javad and Hamane Ajay A, [COMPARATIVE STUDY OF SEISMIC ANALYSIS OF VARIOUS SHAPES OF BUILDING BY INDIAN CODE AND AMERICAN CODE], International Research Journal of Engineering and Technology (IRJET), Volume: 05 Issue: 05 | May-2018.

Bhalchandra p. Alone and Dr. Ganesh Awchat, [Study on seismic analysis of high-rise building by using software], International Journal of Scientific Development and Research (IJSDR), August 2017 IJSDR | Volume 2, Issue 8.

Albert Philip and Dr. S. Elavenil, [SEISMIC ANALYSIS OF HIGH RISE BUILDINGS WITH PLAN IRREGULARITY], International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue 4, April 2017.

R.Kazi, P.V.Muley and P.Barbude, [Comparative Analysis of a Multistorey Building with and without Damper], International Conference on Quality Up-gradation in Engineering, Science and Technology (ICQUEST2015).

Vinay Agrawal, Rajesh Gupta and Manish Goyal, [A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls], International Journal of Engineering and Advanced Technology (IJEAT) ISSN: 2249 – 8958, Volume-6 Issue-6, August 2017.

Nan Jiang, Yuqi Zhang, Chuanbo Zhou, Tingyao Wu and Bin Zhu, [Influence of Blasting Vibration of MLEMC Shaft Foundation Pit on Adjacent High-Rise Frame Structure: A Case Study], Energies 2020, 13, 5140.

Downloads

Published

22-03-2023

Issue

Section

Research Articles

How to Cite

Barmate, V., & Vishwakarma, A. (2023). Analysis of Vibrational Induced Structure Considering Rail and Seismic Load Using ETABS . International Journal of Scientific Research in Civil Engineering, 7(2), 47-54. https://ijsrce.com/index.php/home/article/view/IJSRCE23727

Similar Articles

1-10 of 319

You may also start an advanced similarity search for this article.