Analysis of a Tall Structure Considering Composite Steel Section Columns using ETAB

Authors

  • Parag Jain P.G. Scholar, Department of Civil Engineering, Infinity Management and Engineering College, Sagar, Madhya Pradesh, India Author
  • Rahul Satbhaiya Assistant Professor, Department of Civil Engineering, Infinity Management and Engineering College, Sagar, Madhya Pradesh, India Author

Keywords:

Composite Structure, Analysis, Seismic, ETAB, Tall Structure, Rigidity, Sectional Design

Abstract

The present work carried out to analyze the structural performance of high rise building structure constructed using composite columns in combination with RCC beam & Slab. In this study a model of stilt +10 storied framed structure subjected to seismic loading of Zone – II analyzed using equivalent static method as per IS 1893-2002 on software package ETABS. Two similar models were prepared with different type of columns – RCC Column and CFST Column and similar loading conditions were applied to them. Those two models were analyzed and result obtained were compared in terms of structural performance on following parameters – Maximum story displacement, Story shear, story drift, story overturning moment and section size reduction.              

Downloads

Download data is not yet available.

References

"COMPARATIVE STUDY ON ANALYSIS, DESIGN AND COST OF R.C.C. AND STEELCOMPOSITE STRUCTURE", Yogesh R. Suryavanshi, Prashant S. Patil, Deshmukh Siddheshwar Shrikant, Gaikwad Amol Ramrao, Inamdar Firoj Najmoddin, Puri Sujay Uttam, International Journal of Engineering Research-Online, http://www.ijoer.in, Vol.3., Issue.2, 2015.

"Comparitive study on the behavior of R.C.C, Steel & Composite Structures (B+G+20 Storey)", Sattainathan.A, Nagarajan.N, International Journal on Applications in Civil and Enviornmental Engineering, Volume 1: Issue 3: March 2015, pp 21-26. www.aetsjournal.com.

“Cost, Analysis and Design of Steel-Concrete Composite Structure Rcc Structure”, Anamika Tedia, Dr. Savita Maru, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), e-ISSN: 2278-1684,pISSN: 2320-334X, Volume 11, Issue 1 Ver. II (Jan. 2014), PP 54-59, www.iosrjournals.org.

"Comparative Study of RCC and Composite Multi-storey Buildings", Shashikala. Koppad, Dr. S.V.Itti, International Journal of Engineering and Innovative Technology (IJEIT), Volume 3, Issue 5, November 2013

"Design of Steel Frame Industrial Building Compared With Reinforced Cement Concrete Industrial Building", Ms. S. D. Ambadkar, Prof. Dr. P. S. Pajgade, International Journal of Scientific & Engineering Research, Volume 3, Issue 6, June-2012

IS: 456, Code of practice for plain and reinforced concrete code of practice, Bureau of Indian Standards, New Delhi, 2000.

IS: 1893, Criteria for earthquake resistant design of structures - general provisions for buildings, Part 1, Bureau of Indian Standards, New Delhi, 2002.

IS: 875, “code of practice for design load (other than earthquake) for buildings and structures” Bureau of Indian Standards, New Delhi, 2002.

IS: 800, Code of practice for general construction in steel, Bureau of Indian Standards, New Delhi, 2007.

AISC 360-05, Specification of structural steel building, An American national Standard, American Institute of Steel Construction, Inc., 2005

"Comparision Of R.C.C. And Comosite Multistoried Buildings", Anish N. Shah, Dr. P.S. Pajgade /International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 www.ijera.com, Vol. 3, Issue 2, March -April 2013, pp.534-539

Downloads

Published

06-05-2019

Issue

Section

Research Articles

How to Cite

Jain, P., & Satbhaiya, R. (2019). Analysis of a Tall Structure Considering Composite Steel Section Columns using ETAB . International Journal of Scientific Research in Civil Engineering, 3(3), 01-06. https://ijsrce.com/index.php/home/article/view/IJSRCE19331

Most read articles by the same author(s)

1 2 > >> 

Similar Articles

1-10 of 357

You may also start an advanced similarity search for this article.