Analysis of Diagrid Structure Resist Lateral Forces with Soft Soil Conditions

Authors(2) :-Akash Sharma, Prof. Surendra Ahirwar

As India is a developing nation, there is a drastic development taking place in infrastructure and modern living standards, India is number two in population in the world therefore to settle this population there is a high demand of high rise structure, But in India earthquake prone areas where lateral forces are very high there is a requirement of introducing structures with resisting members which can eliminate the failure of the structure due to sudden forces generated by earthquake, thus, the primary target of this study is to decide the effect of seismic forces (Dynamic Analysis) on the high rise structures. Considering Steel diagrid and hybrid diagrid frame at the outer periphery of structure to resist lateral forces, considering seismic zone V with soft type of soil conditions. Comparative study have been made on an unsymmetrical building of G+11 floors considering seismic zone as per I.S. 1893 part 1 2016. For analysis and modeling purpose STAAD.Pro programming is utilized and study is done on the premise of maximum storey displacement, axial forces, shear forces, maximum bending and displacement and most importantly cost analysis of both the structure as per S.O.R. 2017. In this study we adopt 13 loading combination in each case as per Indian Standards and dimensions of column (450 mm x450 mm), beam (400 mm x300 mm) and diagrid (ISMB 100) in all the cases.

Authors and Affiliations

Akash Sharma
M.Tech. Scholar, Madhyanchal Professional Univercity, School of Engineering & Technology, Bhopal, Madhya Pradesh, India
Prof. Surendra Ahirwar
Department of Civil Engineering, School of Engineering & Technology Bhopal, Madhya Pradesh, India

Hybrid Diagrid, Staad.Pro, Diagrid, Highrise Structure, Structural Analysis, Unsymmetrical Frame, Dynamic Analysis, Conventional Frame.

  1. Syed Ali, M. M. and Moon K. (2007). Structural Developments in Tall Buildings: Currents Trends and Future Prospects. Architectural Science Review, 50.3, pp 205-223.
  2. Connor, J.J. (2003). Introduction to Structural Motion Control. New York: Prentice Hall. 3        Gensler, M. A. (2009). Completing a Supertall Trio, Council on Tall Buildings and Urban Habitat 2009 Chica g Conference: New Challenges in a World of Global Warming andRecession, October 22-23, Chicago.
  3. Kowalczyk, R., Sinn, R., and Kilmister, M. B. (1995). Structural Systems for Tall Buildings. Council on Tall Buildings and Urban Habitat Monograph. New York: McGraw-Hill.
  4. Ravi K Revankar et.al. (2014) Pushover Analysis of Diagrid Structure International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 3.
  5. Montuori et al., (2014) Geometrical patterns for diagrid buildings: Exploring alternative design strategies from the structural point of view Published by Elsevier Ltd.
  6. Shrikant Harle (2014) Analysis and Design of Earthquake Resistant Multi-Storied Braced R.C.C. Building using NISA Software published in international journal of engineering sciences & research technology.
  7. Karoly A. Zalka (2014) Maximum deflection of asymmetric wall-frame buildings under horizontal load periodica polytechnic
  8. Nauman Mohammed et al (2013) Behavior of Multistory RCC Structure with Different Type of Bracing System International Journal of Innovative Research in Science, Engineering and Technology (An ISO 3297: 2007 Certified Organization) Vol. 2, Issue 12

Publication Details

Published in : Volume 6 | Issue 3 | May-June 2022
Date of Publication : 2022-06-30
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 08-26
Manuscript Number : IJSRCE226281
Publisher : Technoscience Academy

ISSN : 2456-6667

Cite This Article :

Akash Sharma, Prof. Surendra Ahirwar, "Analysis of Diagrid Structure Resist Lateral Forces with Soft Soil Conditions", International Journal of Scientific Research in Civil Engineering (IJSRCE), ISSN : 2456-6667, Volume 6, Issue 3, pp.08-26, May-June.2022
URL : https://ijsrce.com/IJSRCE226281

Article Preview

Contact Us

  • Address : 3 & 4, Sterling Plaza, Indira Circle, 150 Feet Ring Road, Rajkot-360005, Gujarat, India