Health Monitoring of An Existing RC Structure Considering Seismic Analysis Using Analysis Tools Staad

Authors(2) :-Sourabh Sahu, Ravindra Kumar Raj

Seismic retrofitting is for the most part done to meet the seismic wellbeing prerequisites. The arranging of changes to existing structures contrasts from new arranging through a significant condition; the current development must be taken as the premise of all arranging and building activities. India is one of the most seismic tremor inclined nations on the planet and has encountered a few significant or moderate quakes during the most recent 15 years. Around 50-60 % of the absolute region of the nation is helpless against seismic movement of changing powers. Many existing structures don't meet the seismic quality prerequisite. In this study we are performing health monitoring on existing old structure G+2, using rebound hammer to evaluate its present strength and analyze the structure using analysis tool staad.pro. In this study we are performing time history analysis (el-centrino) with retrofitting over weak members.

Authors and Affiliations

Sourabh Sahu
P. G. Scholar, Department of Civil Engineering, Babulal Tarabai Institute of Research and Technology, Madhya Pradesh, India
Ravindra Kumar Raj
Assistant Professor, Department of Civil Engineering, Babulal Tarabai Institute of Research and Technology, Madhya Pradesh, India

Time history, staad.pro, Non destructive test, rebound hammer, existing structure, retrofitting, analysis.

  1. Agarwal A. (2012): Seismic Evaluation of Institute Building, Bachelor of Technology Thesis, National Institute of Technology Rourkela.
  2. Agarwal P., Shrikhande M. (2004): Earthquake Resistant Design of Structures, PHI Publication.
  3. Bodige N., Ramancharla P. K. (2012): Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile Detailing, Report No: IIIT/TR/2012/-1, Urban Safety of Mega Cities in Asia (USMCA)
  4. Faella C., Martinelli E., Nigro E. (2002): Steel and concrete composite beams with flexible shear connection: “exact” analytical expression of the stiffness matrix and applications, Computers & Structures - COMPUT STRUCT, vol. 80, no. 11, pp. 1001- 1009, 2002
  5. Fardis M. N. (2009): Seismic Design, Assessment and Retrofitting of Concrete Buildings, Springer Publication.
  6. Griffith M. C., Pinto A. V. (2000):“Seismic Retrofit of RC Buildings - A Review and Case Study”, University of Adelaide, Adelaide, Australia and European Commission, Joint Research Centre, Ispra Italy.
  7. Goel R. K. (2008): Evaluation of Current Nonlinear Static Procedures for Reinforced Concrete Buildings, The 14th World Conference on Earthquake Engineering October 12- 17, 2008, Beijing, China.
  8. Kadid A., Boumrkik A. (2008): Pushover Analysis of Reinforced Concrete Frame Structures, Asian Journal of Civil Engineering (Building and Housing) Vol. 9, No. 1 (2008) Pages 75-83
  9. Krawinkler H., Seneviratna G.D.P.K. (1998): Pros and Cons of a Pushover Analysis of Seismic Performance Evaluation, Engineering Structures, Vol.20, 452-464.
  10. Lawson R.S., Reinhorn A.M., Lobo R.F. (1994): Nonlinear Static Pushover Analysis - Why, When and How? Proceedings of the 5th US National Conference on Earthquake Engineering, Chicago, Vol. 1, 283-292.
  11. Monavari B., Massumi A., Kazem, A (2012): Estimation of Displacement Demand in RC Frames and Comparing with Target Displacement Provided by FEMA-356, 15th World Conference on Earthquake Engineering, 24th to 28th September, 2012, Lisbon, Portugal.
  12. Mouzzoun M., Moustachi O., Taleb A. (2013): Seismic Damage Prediction of Reinforced Concrete Buildings Using Pushover Analysis, International Journal of Computational Engineering Research (ijceronline.com) Vol. 3 Issue. 1, January 2013.
  13. Mouzzoun M., Moustachi O., Taleb A., Jalal S. (2013): Seismic performance assessment of reinforced concrete buildings using pushover analysis, IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE); ISSN: 2278-1684 Volume 5, Issue 1 (Jan. - Feb. 2013), PP 44-49.
  14. Mwafy A. M., Elnashai A. S. (2001): Static Pushover versus Dynamic Analysis of RC Buildings, Engineering Structures, Vol. 23, 407-424.
  15. Otani S. (2000): Seismic Vulnerability Assessment of Reinforced Concrete Buildings, Faculty of Engineering, University of Tokyo, Series B, Vol., XLVII, October 2000, pp. 5 - 28.
  16. Pillai S. U., Menon D. (2009): Reinforced Concrete Design, TMH Publication.
  17. Poluraju P., Nageswara Rao P. V. S. (2011): Pushover analysis of reinforced concrete frame structure using SAP 2000, International Journal of Earth Sciences and Engineering, ISSN 0974-5904, Volume 04, No 06 SPL, pp. 684-690.
  18. Rai, Durgesh C. (2005): “Seismic Evaluation and Strengthening of Existing Buildings” IIT Kanpur and Gujarat State Disaster Mitigation Authority.
  19. Amlan K. Sengupta, Chemuru Srinivasulu Reddy, Badari Narayanan V T and Asokan A, (2004)―seismic analysis and retrofit of existing multistoried buildings in India – an overview with a case‖
  20. S. Anbarasu, K.Tamilvanan, “Seismic Retrofitting of Reinforced Concrete Frame Building with Soft Storey”, International Journal of Innovative Research in Science, Engineering and Technology, vol. 5, issue 3, March 2016.
  21. Kritika Gupta, Abhishek Kumar, Mohd Afaque khan, “Review paper on seismic retrofitting of structures” Volume:04/April-2017.

Publication Details

Published in : Volume 5 | Issue 5 | September-October 2021
Date of Publication : 2021-09-30
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 136-143
Manuscript Number : IJSRCE215525
Publisher : Technoscience Academy

ISSN : 2456-6667

Cite This Article :

Sourabh Sahu, Ravindra Kumar Raj, "Health Monitoring of An Existing RC Structure Considering Seismic Analysis Using Analysis Tools Staad", International Journal of Scientific Research in Civil Engineering (IJSRCE), ISSN : 2456-6667, Volume 5, Issue 5, pp.136-143, September-October.2021
URL : https://ijsrce.com/IJSRCE215525

Article Preview

Contact Us

  • Address : 3 & 4, Sterling Plaza, Indira Circle, 150 Feet Ring Road, Rajkot-360005, Gujarat, India