Seismic and Wind Analysis of Natural Draught Cooling Tower with Change in Dimensional Ratio

Authors(2) :-Mohd Atif Hussain, Prof. Rashmi Sakalle

In this study, a static linear Eigen value buckling parametric analysis is done for cooling tower shell geometries of 150 m height. The shells are subjected to wind pressures (speeds) of (47 meter per second) and seismic vibrations under zone IV to observe the trends in the critical buckling pressures/speeds at which the shell first buckles and therefore the corresponding buckling modes. The cooling tower’s geometry is changed in a systematic manner along the height to obtain the relationship between applied wind speeds and seismic vibrations associated with the mode of buckling and the cooling tower’s geometry. Geometrical parameter ratios of the cooling tower’s dimensions are considered so as to hide a wider spectrum of the cooling tower’s geometry. The critical wind speed and seismic vibrations versus height curve is observed to be similar to the Euler buckling curve. There is an assumed diameter to total height ratio of about 1.15 instead of 1.5 for any cooling tower at which the critical wind speed is maximum. The critical wind speed varies linearly with the cooling system thickness and non-linearly with all diameter ratios. A linear eigen value vibration, parametric analysis is expressed for various cooling tower shell geometries to analyse trends in the free vibration response (natural frequencies and mode shapes). The forced response of the cooling tower to various forcing frequencies of wind and seismic vibrations is analysed using the mode analysis method using Staad.pro software. The shells are subjected to increasing wind gust periods of an equivalent speed to get the trends within the forced vibration response. In a systematic ladder manner, the cooling tower geometry is changed to obtain the free and forced vibration behaviour. The natural frequencies and their corresponding for the four different modes reduce with increasing height based on the loads applied. They are generally invariant with the peak to top diameter ratio, but the bandwidth increases with increasing height to top diameter ratio. The static response frequencies and their corresponding generally increase with increasing height as well as the height to base diameter ratios. The static response frequency generally decreases with decreasing forcing frequency.. The findings can be used as a basis for further research and establishment of conceptual design guidelines when considering stability, free and forced vibration cooling tower_behaviour.

Authors and Affiliations

Mohd Atif Hussain
Civil Engineering Department, Truba Institute of Engineering & technology, Bhopal, Madhya Pradesh, India
Prof. Rashmi Sakalle
Civil Engineering Department, Truba Institute of Engineering & technology, Bhopal, Madhya Pradesh, India

hyperbolic cooling tower, stability, buckling, modes, critical wind pressure, speed/velocity, seismic vibrations, static response, natural frequency, mode shape

  1. International Journal of Scientific & Engineering Research, Volume 4, Issue 5, May-2013, pp 1560-1563.
  2. Static and Dynamic Analysis of Hyperbolic Cooling Tower” by Sachin Kulkarni, and Prof A. V. Kulkarni; presented a paper in the Proceedings of the 2nd International Conference on Current Trends in Engineering and Management ICCTEM -2014   17 – 19, July 2014, Mysore, Karnataka, India, pp-9-26.
  3. Effect of Wind Loading on Analysis of Natural Draught Hyperbolic Cooling Tower by Tejas G. Gaikwad, N. G. Gore, V. G. Sayagavi, KiranMadhavi and Sandeep Pattiwar; in International Journal of Engineering and Advanced Technology (IJEAT) ISSN: 2249 – 8958, Volume-4 Issue-1, October 2014, pp 34-39.
  4. A Case Study Of Hyperbolic Cooling Tower Under Seismic Loads by IqbalHafeez Khan, Rakesh Patel, and Aslam Hussain in International Journal of Engineering Sciences & Research Technology, 5(1): January, [2016] ISSN: 2277-9655, pp 917-932
  5. “Review on Natural Draft Hyperbolic Cooling Towers” by Amritha Treesa, and Akshara S P; in International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 – 0056, Volume: 04 Issue: 06; June – 2017.
  6. IS: 11504 -1987.
  7. IS: 1893 - 2002 (Part - IV)
  8. IS: 875 - 2005 (Part - III)

Publication Details

Published in : Volume 5 | Issue 2 | March-April 2021
Date of Publication : 2021-03-30
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 92-103
Manuscript Number : IJSRCE215221
Publisher : Technoscience Academy

ISSN : 2456-6667

Cite This Article :

Mohd Atif Hussain, Prof. Rashmi Sakalle, "Seismic and Wind Analysis of Natural Draught Cooling Tower with Change in Dimensional Ratio", International Journal of Scientific Research in Civil Engineering (IJSRCE), ISSN : 2456-6667, Volume 5, Issue 2, pp.92-103, March-April.2021
URL : https://ijsrce.com/IJSRCE215221

Article Preview

Contact Us

  • Address : 3 & 4, Sterling Plaza, Indira Circle, 150 Feet Ring Road, Rajkot-360005, Gujarat, India