Finite Elemental Analysis of Industrial Structure Using Cold Formed Steel

Authors

  • Pradeep Patidar Department of Civil Engineering, Alpine Institute of Technology, Ujjain Madhya Pradesh, India Author
  • Komal Bedi Department of Civil Engineering, Alpine Institute of Technology, Ujjain Madhya Pradesh, India Author

Keywords:

Staad, C.F.S, Industrial frame, Analysis, Forces, Deflection, Cost

Abstract

Increasing world population and natural resource limitations has led to a growing demand for more efficient structural systems to achieve a sustainable economy and society. Cold-formed steel CFS) Structural systems are increasingly adopted as primary or secondary structural members in modern building construction because of their light weight, speed of construction, recyclability, and sustainability. However, the inherently low buckling resistance of thin sections results in relatively low strength and ductility in CFS elements, which limits their performance in tall buildings and under extreme loading events. The pre-engineered steel building system construction has great advantages to the single storey buildings, practical and efficient alternative to conventional buildings, the System representing one central model within multiple disciplines. Pre-engineered building creates and maintains in real time multidimensional, data rich views through a project support is currently being implemented by Staad pro software packages for design and engineering.In this research work we will design Industry using analysis tool Staad.pro and use Novel cold formed steel structure and compare it with general steel available in Indian market. Here we will compare both in terms of strength and weight of structure with bolted and welded connections.              

Downloads

Download data is not yet available.

References

M.G.Kalyanshetti, G.S.Mirajkar (2012, November-December).Comparison between Conventional Steel Structures and Tubular Steel Structures. International Journal of Engineering Research and Applications. Volume 2 (Issue 6), pp.1460-1464. www.ijera.com/papers/Vol2_issue6/HK2614601464.pdf.

IS 800-1984, Code of practice for general construction in steel.

Code of practice for design loads (other than earthquake) for buildings and structures (part-1) IS 875-1987.

Code of practice for design loads (other than earthquake) for buildings and structures (part-2) IS 875-1987

Code of practice for design loads (other than earthquake) for buildings and structures (part-3) IS 875-1987.

Code of practice for use of steel tubes) for buildings and structures IS 806, 1968.

Dan Dubina et al (2007).”Analysis and Design of Steel Structure”.

Gary S. (2010), ”Analysis and Design of Steel Structure” OnlineAvailable at http://raselpics.ru/steel-design-structures-practice.pdf

IIT-Kharagpur, Design of Steel structures, “NPTEL online material for the students”, Module27. OnlineAvailable at www.scribd.com/doc/292540965/Structural-Analysis-an-Industrial-Building

Subramanian.N (2008) “Design of Steel Structure”.

Downloads

Published

25-02-2019

Issue

Section

Research Articles

How to Cite

Patidar, P., & Bedi, K. (2019). Finite Elemental Analysis of Industrial Structure Using Cold Formed Steel . International Journal of Scientific Research in Civil Engineering, 3(1), 35-38. https://ijsrce.com/index.php/home/article/view/IJSRCE19317

Similar Articles

1-10 of 354

You may also start an advanced similarity search for this article.