Effect of Thermal Bridges on the Heat Balance of Buildings

Authors(2) :-Malek Jedidi, Omranne Benjeddou

Thermal bridges in the thermal insulation of envelopes occur in all forms of building construction and should be minimised to reduce local heat losses. This paper presents the effect of thermal bridges on the comfort of the habitat within a building. Indeed, the thermal bridges increase the heat losses of a building and thus the consumption of heating. Thermal bridges cause additional heat losses compared to losses through the walls of the building. These losses can exceed for some 40% of the total heat losses through the envelope. An example of an energetic effect of a thermal bridge has been presented. For this example, the heat losses on a floor height and per meter of facade were calculated. The results showed that from 5 cm thickness of insulation, the difference between the loss curve in the absence of thermal bridge, and the loss curve taking into account the thermal bridge is almost independent of the thickness of the insulating. Another example was also presented to demonstrate the effect on thermal bridging when increasing the levels of insulation to a normal corner. The results showed that for a 50% and 100% increase in the thickness of the insulation, the U-value, linear heat loss coefficient ? and surface temperature factor fRsi were considerably decreased.

Authors and Affiliations

Malek Jedidi
Higher Institute of Technological Studies of Sfax, Department of Civil Engineering, Sfax, Tunisia
Omranne Benjeddou
University of Tunis El Manar, National Engineering School of Tunis, Civil Engineering Laboratory, Tunis, Tunisia

Thermal Bridges, Linear Heat Loss Coefficient , Heat Losses, Insulation, Surface Temperature Factor, Buildings.

  1. Martin, K.; Erkoreka, A.; Flores, I.; Odriozola, M.; Sala, J.M. Problems in the calculation of thermal bridges in dynamic conditions. Energy Build. 2011, 43, 529-535.
  2. Martin, K.; Campos-Celadorb, A.; Escuderoa, C.; Gmezb, I.; Sala, J.M. Analysis of thermal bridge in a guarded hot box testing facility. Energy Build. 2012, 50, 139-149.
  3. Evola, G.; Margani, G.; Marletta, L. Energy and cost evaluation of thermal bridge correction in Mediterranean climate. Energy Build. 2011, 43, 2385-2393.
  4. Bianchi, F.; Pisello, A.; Baldinelli, G.; Asdrubali, F. Infrared Thermography Assessment of Thermal Bridges in Building Envelope: Experimental Validation in a Test Room Setup. Sustainability 2014, 6, 7107-7120. [CrossRef]
  5. Cuce, E.; Cuce, P. The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research. Energy Build. 2016, 116, 449-454. [CrossRef]
  6. Lorenzati, A.; Fantucci, S.; Capozzoli, A.; Perino, M. Experimental and numerical investigation of thermal bridging effects of jointed Vacuum Insulation Panels. Energy Build. 2016, 111, 164-175.
  7. Quinten, J.; Feldheim, V. Dynamic modelling of multidimensional thermal bridges in building envelopes: Review of existing methods, application and new mixed method. Energy Build. 2016, 110, 284-293.
  8. Martins, C.; Santos, P.; da Silva, L. Lightweight steel-framed thermal bridges mitigation strategies: A parametric study. J. Build. Phys. 2016, 39, 342-372.
  9. Swiss Standards AssociationS. wisscode SIA 180. Isolation thermique et protection contre l'humidit dans les btiments. Swiss Society of Engineers and Architects (1999)
  10. Grinzato E., Vavilov V., Kauppinen T., 1998, "Quantitative infrared thermography in buildings", Energy and Buildings, Vol 29, pp 1-9.
  11. Albatici R., Tonelli A.M., 2010, "Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site", Energy and Buildings, Vol 42, pp 2177-2183.
  12. Zalewski L., Lassue S., Rousse D., Boukhalfa K., 2010, "Experimental and numerical characterization of thermal bridges in prefabricated building walls", Energy Conversion and Management, Vol 51, pp 2869-2877.
  13. Swiss Standards Association. Swisscode SIA 380/1 L'nergie thermique dans les btiments. Swiss Society of Engineers and Architects, Zurich, Switzerland (2009).
  14. Energy Saving Trust. (2009) Enhanced Construction Details: Thermal Bridging and Airtightness. CE302. London: Energy Saving Trust.
  15. Anderson, B. (2006) Conventions for U-value Calculations. BR 443. Watford: Building Research Establishment.

Publication Details

Published in : Volume 2 | Issue 5 | 2018
Date of Publication : 2018-11-30
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 41-49
Manuscript Number : IJSRCE182517
Publisher : Technoscience Academy

ISSN : 2456-6667

Cite This Article :

Malek Jedidi, Omranne Benjeddou, "Effect of Thermal Bridges on the Heat Balance of Buildings", International Journal of Scientific Research in Civil Engineering (IJSRCE), ISSN : 2456-6667, Volume 2, Issue 5, pp.41-49, .2018
URL : https://ijsrce.com/IJSRCE182517

Article Preview

Contact Us

  • Address : 3 & 4, Sterling Plaza, Indira Circle, 150 Feet Ring Road, Rajkot-360005, Gujarat, India